NEWS

Winnipeg Fire Paramedic Service responds to fire on Wolseley Avenue West

MANITOBA SERVICES

POSTED ON NOVEMBER 12, 2021 BY MANNY

Released 07:45AM

winnipeg fire truck.jpg

Winnipeg, MB – At 5:02 a.m. on Friday, November 12, 2021, the Winnipeg Fire Paramedic Service responded to reports of a fire in a single-family, two-storey home in the 1500 block of Wolseley Avenue West.  

When crews arrived on scene, they encountered smoke coming from the house. They launched a defensive attack until it was safe to enter the house and fight the fire offensively. Firefighters were aided by the use of Flameguard X-Tinguish Fire Suppression Tool (FST), an aerosol device that reduces temperatures, which allows for safer access. The FST generates a mist that expands to flood the space, suppressing flames within seconds. The fire was declared under control at 5:45 a.m.

Occupants of the home safely self-evacuated prior to the arrival of crews. Firefighters located one cat deceased in the home. No other injuries were reported.

The cause of the fire remains under investigation. Damage estimates are not currently available but the house suffered significant fire, smoke and water damage.

Two firefighters taken to hospital after blaze at College Avenue home.                                                                                                                                                      

By Kevin Hirschfield  Global News

Posted May 17, 2021 10:53pm
 

winnipeg fire truck.jpg

One person was sent to hospital in stable condition and another was treated by paramedics at the scene of an apartment fire in St. Vital early Monday morning. Elisha Dacey/Global News

Two firefighters were taken to hospital with minor injuries after a fire at a home in the 400-block of College Avenue Monday night.

Crews were called to the one-and-a-half storey home just after 7 p.m. and used a Flameguard X-Tinguish Fire Suppression Tool, an aerosol device that reduces temperatures, which allows safer access for firefighters.

Everyone in the home was able to evacuate safely before crews arrived.

The cause of the fire is under investigation.

© 2021 Global News, a division of Corus Entertainment Inc.

House damaged, but no one hurt in Friday morning Winnipeg blaze

By Sam Thompson  Global News

Posted April 30, 2021 4:47 pm

A one-and-a-half-storey house on Church Street suffered significant water, smoke and fire damage after a Friday morning blaze, Winnipeg firefighters said.

Just before 10 a.m., the Winnipeg Fire Paramedic Service (WFPS) arrived at the house in the 400 block of Church, where crews encountered heavy smoke and flames.

With the help of an aerosol fire-suppression tool, the Flameguard X-Tinguish FST, fire crews were able to reduce temperatures so firefighters could get inside safely, and the fire was under control by 11:22.

There were no injuries in the incident, although the building was damaged and neighbouring houses also suffered heat damage.

winnipeg%20vehicles_edited.jpg
winnipeg%2043021%201_edited.jpg

Normandale house fire

Damage pegged at $150,000

Author of the article: Monte Sonnenberg

Publishing date: Mar 31, 2021 

normadale_edited.jpg

James Robertson, assistant fire chief in Norfolk County, says the deployment of a fire-suppression "grenade" like this was instrumental in bringing a serious basement fire in Normandale under control in the early morning hours of Wednesday. The fire on Mole Side Road caused an estimated $150,000 damage and killed a family pet. – Monte Sonnenberg

NORMANDALE – An electrical malfunction has been cited in a fire in Normandale Wednesday that left a family pet dead.

The Norfolk County Fire Department reports the alarm was called in shortly after midnight. The occupants were able to evacuate with minor burns and smoke inhalation.

“Upon arrival, firefighters discovered a working basement fire,” assistant fire chief James Robertson said in a news release. “Firefighters were able to quickly bring the fire under control by utilizing a throwable fire ‘grenade’ before the fire spread to the main floor.”

In an interview, Robertson said the pet that perished was a 30-year-old parrot. Robertson said the parrot had been with the owner since it was a fledgling.

The fire occurred at 23 Mole Side Road west of the hamlet. Two people in the home were using the basement as a temporary bedroom.

The blaze presented Norfolk firefighters with a rare opportunity to deploy a fire-fighting device which, in this case, greatly limited damage to the property and saved the home.

 

The “grenade” Robertson referred to goes by the brand name X-Tinguish X-Treme.

In the right circumstances, Robertson said the grenade will temporarily knock back a fire if it is in a confined location, giving firefighters an opportunity to enter the building and deal with the problem directly. He said the Norfolk department has occasion to use the grenade about once a year.

In this case, the pin was pulled on the 14-pound device and thrown into the centre of the fire through a basement window. Once the device activates, it discharges fire-retardant chemicals in all directions for about half a minute. A spec sheet says the grenade will reduce ambient temperatures in the area of a fire by 1,000 degrees F for 60 seconds.

“You have to get it in or on top of the fire,” says Robertson, adding Norfolk firefighters have had the device at their disposal for 10 years.

“They were able to put one on the nose of this fire. It’s another tool at our disposal.”

The concept is not new. In the late 19th century, property owners could purchase large glass orbs filled with salt water that were thrown at a fire in a confined location. The idea was to have enough of the orbs on hand to extinguish the fire or at least knock the flames back to allow escape.

The devices later came with fire-retardant chemicals but the fumes arising from them were toxic at high temperatures.

“This is the modern, high-tech version of that,” says Norfolk fire prevention officer Cory Armstrong-Smith. “Could you imagine a fire truck full of those glass balls? What a mess that would be.”

The occupants in Normandale were examined by paramedics but declined a visit to hospital.

Total damage is estimated at $150,000. Inspectors have concluded the fire was electrical in nature. The county department says the occupants were insured.

No firefighters were injured. Crews responded from Station 11 in Vittoria and Station 5 in Delhi. The owner of the property declined a request to speak to a reporter.

MSonnenberg@postmedia.com

Fire grenades and aerosol mist: Launching new fire suppression tools

In confined spaces, these mini extinguishers can save lives and property

Mar 24, 2021

By Robert Avsec , FireRescue1.com

From the earliest days of “put the wet stuff on the red stuff,” there’s been the search for the next best thing in extinguishing agents. This has been especially true for the protection of high value fixed facilities once it became apparent that automatic fire sprinklers could exact more damage on the property (e.g., communications equipment and electronics) than the heat and smoke from a fire. And that quest created a domino effect of products, from Halon to “fire grenades” and condensed aerosol mist.

THE USE – AND BAN – OF HALON

In 1954, the U.S. Army and DuPont collaborated to develop Halon 1301 to provide fire suppression capabilities for high-value military assets (e.g., aircraft, mainframe computers and telecommunication switching centers) as total flooding systems. Halon (short for halogenated hydrocarbon) was liquefied gas used to extinguish fires by chemically interrupting the combustion chain reaction – the fourth side of the fire tetrahedron.

Halon, in its various forms, was an extremely popular extinguishing agent because it was nonconducting and left no residue after being discharged. In fact, Halons were popularly described as a "clean” extinguishing agent.

Fixed fire suppression systems using Halon 1301 and its halogenated hydrocarbon “cousin,” Halon 1211, made their first entries into non-military fire suppression applications in the 1960s, quickly gaining traction with facility managers charged with protecting high-value assets. And with many of those assets containing sensitive electronics and computer technologies, assets that would be damaged or destroyed by the activation of a traditional fire sprinkler system, Halons quickly became the “gold standard” for the protection of such facilities.

In 1987, representatives from around the world met and developed an international treaty, The Montreal Protocol on Substances that Deplete the Ozone Layer, which quickly became known as the Montreal Protocol. The goal of the treaty was to gradually eliminate the production and consumption of ozone-depleting substances to limit their damage to the earth’s ozone layer.

The United States was among the 197 countries to sign the Montreal Protocol – the first treaty in the history of the United Nations to achieve universal ratification – and has been a leader in guiding the successes of the treaty. In 1994, the U.S. EPA banned the production and import of Halons 1211 and 1301 to comply with the Montreal Protocol, prompting chemists and f